Model EC5500R Digital Indicating Controller has a large-sized display excellent in visibility. Since it is a light guide system, it is clear also outdoors. And dial setting is fulfilled easy operation. In addition, self-tuning is equipped as a standardly. PID, gapped PID, heat/cool control or servo PID are available as control functions. As described above, the EC5500R 1/4DIN controller is applicable to a broad use.
FEATURES
Extra-Large digital display
Auto-Tuning, Self-Tuning provided as standard
Full Multi-Input (Thermocouple, RTD, voltage or current)
Scaling Range of -1999 to 9999
Multi- Output (Selective)
4 Alarm Output
RS-232C,RS- 422A (RS-485) Communication Interface
Easy Replace from EC5500S
SPECIFICATIONS
Input range: Full multi-range, refer to Range table
Display: 7-segment LED, process variable(PV) / green,
set point(SP)& output/ orange
Sampling Rate:250ms
Scaling: -1999 to 9999 with mV, V & mA ranges
Set point: Front panel (local) or remote (optional)
Set point bias: ± 20% available with remote set point
Set point tracking: Remote to local
Set point limiter: 0~100% with TC & RTD input ranges
Multi set point: Up to 8 set points
Sensor correction: ± 100°C with TC & RTD input ranges
Set point ramping: 0.01 ~ 650.0 unit/min. Unit °C or %
Control: PID, gapped PID, PD, 3-position (dual output)
or ON/OFF
Proportional band: 0.1~999.9%
Integral (reset): 0.01 ~99.99 min.
Derivative :(rate): 0~20.00 min.
Manual reset: 0~100%, PD control mode only
Dead band: ± (0~0.500), heat/cool control mode
Hysteresis: 0.00~20.00% ,ON/OFF control mode
PlD adjustment: Independent on each set point
Programmed PID: 8 PID parameters can be selected
automatically to optional remote set point
PID tuning: Selectable Auto tuning or Self tuning
Output: Selectable output from among
Relay; a-contact, 250VAC, 3A resistive load
SSR Drive; 15VDC, 20mA max.
Current; 4~20mA/600Ω or 0~5mA/2kΩ
Servo drive output: Option
Dual output: Any combination from among relay, SSR
drive and current output
Auto/Manual: Balance less bump less transfer
Output limiter: 0~100%
Direct/Reverse: Selectable, reverse in Dual output model
Cycle time: 1~120 sec., relay and SSR drive output
RUN/STOP: Controller enable/disabled
Preset manual: 0~100%, available when controller
disabled
Alarm: 4 set point process variable or deviation alarm
Alarm set point: Process variable alarm, 0~100% of range,
deviation alarm, ± 100% of range
Hysteresis: 0~100% adjustable within the range
Alarm on delay timer: 0~600 sec.
Nos. of output relays: 4 relays, driven from among each
alarm and controller status(2 relays are
optional)
Relay rating: a-contact, 250VAC 0.5A, resistive load, One side
contact are common.
Status Output: AUTO/MAN, RUN/STOP, Watchdog timer
& Reach at set point (available on set point ramping)
Digital input: 4 input for set point selection, PID parameter
selection, AUTO/MAN switching, Remote
/Local switching, or RUN/STOP switching,
Non-voltage contact input 15VDC 1mA
Memory backup: Non-volatile RAM(Fe-RAM)